What was found
CORROSION ON R/H TRANSITION ANGLE STA 727G-727H / [01] CORROSION FOUND TO BE OUT OF LIMITS. REMOVED R/H TRANSITION ANGLE FROM STA 727E+10 TO STA 767 FOR REPLACEMENT PER SRM 51-40-02.;[02] LOCATED HOLES ON NEW TRANSITION ANGLE STA 727E+10 TO 767 PER SRM 51-40-02.;[03] INSPECTED WORK PERFORMED ON C/A #2;[04] ALODINED AND PRIMED NEW TRANSITION ANGLE PER SRM 51-00-53-2R-5 AND SRM 51-20-01.;[05] INSPECTED WORK PERFORMED ON C/A # 4;[06] INSTALLED BONDED NUTPLATES ON NEW TRANSITION ANGLE PER SRM 51-40-10-2R-0.;[07] INSPECTED WORK PERFORMED ON C/A #6;[08] OK TO INSTALL TRANSITION ANGLE;[09] #4 CORRECT SRM REFERENCES: ALODINED AND PRIMED NEW TRANSITION ANGLE PER SRM 53-00-53-2R-5 AND SRM 51-20-01.;[10] COMPLIED WITH MEASUREMENTS.;[11] INSTALLED NEW TRANSITION ANGLE STA 727E+10 TO 767 PER SRM 53-00-53-2R-5 .;[12] INSPECTED WORK PERFORMED ON C/A #9;C/A #10; C/A #11;[13] CERTIFIED;[14] INSPECTED THE FASTNER INSTALLATION R/H TRANSITION ANGLE INBOARD FRAME LOCATIONS FROM STATION 727E TO STATION 767. NO DEFECTS NOTED.;[15] PERFORMED BONDED NUTPLATE PUSH TEST PER SRM 51-40-10-2R-0.;[16] REMOVED AND REPLACED RH TRANSITION ANGLE STA 727E +10 TO STA 767 PER SRM 53-00-53-2R-5.;[17] INSPECTED WORK PERFORMED;[18] INSPECTED WORK PERFORMED