What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 LBL 46 FWD GALLEY AND LAV 2022-158494 / [01] REPLACE WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 LBL 46 FWD GALLEY AND LAV I.A.W. B737-700 SRM 51-10-02 AND DWG DWG 141A5400 SHEET:26 REV: -.;[02] CORRECTED STEP 1. REPLACE WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 LBL 46 FWD GALLEY AND LAV I.A.W. B737-700 SRM 51-10-02 AND DWG DWG 141A5400 SHEET:26 REV: -. SEE INDIVIDUAL SING OFFS BELOW.;[03] REPLACE WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328 LBL 46 FWD GALLEY AND LAV I.A.W. B737-700 SRM 51-10-02 AND DWG DWG 141A5400 SHEET:26 REV: -. <BR>RII ACCOMPLISHED <BR>SEE INDIVIDUAL SING OFFS BELOW.