What was found
CRACK ON FWD CARGO BAY INTERCOSTAL AT RBL 23 BS 400+1. / [01] REMOVED FCB INTERCOSTAL AT RBL 23 BS 400 - BS 420 I.A.W SRM 51-40-02-0G-0;[02] LOCATED AND DRLLED ON FWD CARGO BAY NEW INTERCOSTAL BS 400 TO BS 420 RBL 23 WL 156 P/N 143A7510-34 LOT#1487853-1 PO#863642/1 IAW SRM 51-40-05 AND DWG143A7505 REV:B. OK TO INSTALL;[03] VERIFIED CORRECTIVE ACTION ITEM 2. OKAY TO INSTALL NEW INTERCOSTAL AT RBL 23 BS 400 - BS 420 GIVEN.;[04] INSTALLED ON FWD CARGO BAY NEW INTERCOSTAL BS 400 TO BS 420 AT RBL 23 WL 156 IAW SRM 51-40-02 AND DWG 143A7505 REV:B.;[05] SRM 53-00-53-1A-2 IA IS APPLICABLE; NO ALLOWABLE DAMAGE PER SRM; PART TO BE REPLACED IAW SRM 51-10-02 PAR.9<BR><BR>LOCATED AND DRLLED ON FWD CARGO BAY NEW INTERCOSTAL BS 400 TO BS 420 RBL 23 WL 156 P/N 143A7510-34 LOT#1487853-1 PO#863642/1 IAW SRM 51-40-05 AND DWG143A7505 REV:B. OK TO INSTALL;[06] UPDATED MEASUREMENTS;[07] VERIFIED CORRECTIVE ACTION ITEMS 4 AND 5. INSTALLATION OF INTERCOSTAL AND SRM APPLICABILITY.