What was found
CRACKED INTERCOSTAL AT BS 294.5-312; RBL 15; WL 208.1. INSTALLED FOD PROTECTION FROM BS277 - BS328, BL 0 - RBL 30, WL 198 IAW AMM 20-60-07-913-801. REMOVED ALL FASTENERS FROM INTERCOSTAL IAW SRM 51-40-02-0G-0. REMOVED STIFFENER AT BS 312 RBL 24 AND INTERCOSTAL AT BS 294.5-BS312 RBL 36 IAW SRM 51-40-02-0G-0, LOCATED AND DRILLED NEW INTERCOSTAL IAW SRM 51-40-05-0G-0. INSTALLED THE INTERCOSTAL IAW SRM 51-40-02 AND DRAWING 141A5400 SH. 9.