What was found
A-061 DOT 033 AFT CARGO PIT BAFFLE UNDER R/H Z ANGLE BETWEEN STA 747 AND STA 767 RBL 23 WL 155 CORRODED AT NUTPLATES HOLES / [01] REMOVED DAMAGE PART IAW SRM 51-40-02-0G-0;[02] REMOVED CORROSION ON DAMAGE PARTS IAW SRM 51-10-02-0G-0 ITEM 15;[03] EVALUATED ALLOWABLE LIMITS: .040 ORIGINAL 'T' .025 REMAINING .015 LOSS FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 TOOL USED MICROMETER#AAR24510 DUE 01-25-23;[04] VERIFIED STEPS 1-3 ARE COMPLETE;[05] VERIFIED ITEMS 1 THROUGH 4;[06] ADDED P/N TO MEASUREMENTS TABLE;[07] VERIFIED NEW BAFFLE (SPLICE) P/N146A7505-12 WN 14818 IAW DWG 146A7500 REV:-;[08] VERIFIED STEPS 6 AND 7;[09] LOCATED AND DRILL HOLES ON NEW SPLICE IAW SRM 51-40-05-0G-0;[10] VERIFIED STEP 9.<BR>OK TO INSTALL REPLACEMENT PART.;[11] INSTALLED NEW SPLICE ( BAFFLE) IAW SRM 51-40-02-0G-0 AND DWG 146A7500 REV:-;[12] VERIFIED INSTALLATION OF PART IN STEP 11.<BR>OK TO CIC AREA.;[13] APPLIED CIC AREA IAW AMM 51-21-91-620-802;[14] VERIFIED STEP 13. <BR>VERIFIED REPLACEMENT OF SPLICE. <BR>AUDIT C/W.;[15] CHANGED CORROSION LEVEL