What was found
EMERGENCY EXIT IDENTIFIERS AT FWD SERVICE DOOR; L/H OVERWING HATCHES; AND R/H OVERWING HATCHES MISSING LAMPS. / [01] REMOVED AND REPLACED ALL INOP EMERGENCY EXIT IDENTIFIER LIGHT LAMPS AT FWD SERVICE DOOR AND R/H OVER-WING HATCH. UPON TROUBLESHOOTING FOUND 2 DAMAGED EMERGENCY EXIT IDENTIFIER LIGHT ASSEMBLIES BOTH DAMAGED LIGHT ASSEMBLIES ON L/H OVER WING HATCHES. REMOVED AND REPLACED BOTH ASSEMBLIES AND PERFORMED GOOD OPERATIONAL TEST OF ALL EMERGENCY EXIT IDENTIFIER SIGNS PER AMM 33-51-01-960-802 AND AMM 33-51-01-960-801.;[02] VERIFIED CORRECTIVE ACTION ENTRY 1. CARD COMPLETE.