What was found
LEFT PACK BAY; HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK AT BS 663, LBL 10 CRACKED. REMOVED DAMAGE IAW SRM 57-10-10-2R-5 FIG 202 SH 6. LOCATED, DRILLED & TRIMMED ANGLE IAW SRM 57-10-10-2R-5 FIG 202 SH 6. LOCATED, DRILLED & TRIMMED SPLICE ANGLE IAW SRM 57-10-10-2R-5 FIG 202 SH 6. TREATED & PRIMED REPAIR PARTS & CUTOUT IAW SRM 57-10-10-2R-5 STEO 4F-4G. INSTALLED REPAIR PARTS IAW SRM 57-10-10-2R-5 STEP 4L(1)-4L(7). BOND CHECK GOOD IAW SRM 57-10-10-2R-5 STEP 4M AND FIG 202 SH 6 FN 1. SEALED AND FILLET SEALED FASTENERS EXTERNALLY. SEALED FUEL TANK FASTENERS INTERNALLY IAW SRM 57-10-10-2R-5 STEP 4L(8). PERFORMED FUEL LEAK CHECK PER AMM 28-11-00/601. NO LEAKS NOTED.