What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 460+14; BS 480+6; BS 480+10; BS 500+5; BS 500+10; BS 500+14; BS 500+18; BS 500A+2; BS 500A+6; BS 500A+10. / [01] REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS480+6 MEASURED1.7'L X 0.9'W AND 0.010'DEEP ORIGINAL THICKNESS OF 0.040' FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2<BR><BR>REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS480+10 MEASURED1.3'L X 0.9'W AND 0.0065'DEEP ORIGINAL THICKNESS OF 0.040' FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2REMOVED CORROSION FROM FCB L/H FLOOR TO SIDEWALL SUPPORT AT BS500A+2 MEASURED1.8'L X 0.8'W AND 0.005'DEEP ORIGINAL THICKNESS OF 0.040' FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2[05] NEW FCB LH FLOOR TO SIDEWALL SUPPORT BS 400- BS 500D WILL BE FABRICATED ON CUSTOMER CARD: TTG8Q00BL4G9;[06] VERIFIED ITEM 5 CORRECTIVE ACTIONS.