What was found
PASSENGER CABIN FLOOR PANEL; 221BF; AFT OUTBOARD CORNER IS MISSING. / [01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>REMOVED 7EA THROUGH INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-6 PARA 3B.<BR>REMOVED DAMAGED SKIN AND CORE AROUND AFT O/B CORNER; CLEANED REPAIR AREA IAW SRM 53-00-50-2R-6 PARA 3C-E.;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-6.;[03] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1 AND 2. OKAY TO PROCEED PER SRM 53-00-50-2R-6.;[04] FABRICATED CORE PLUG OUT OF BMS 8-124 CL4 TY5 GR5 LOT#1283769; AND FABRICATED UPPER SURFACE REPAIR PLIES OUT OF BMS 9-3 ST 1581 LOT#1475360-2 IAW SRM 53-00-50-2R-6 PAR 4F. OK TO INSTALL.;[05] VERIFIED CORRECTIVE ACTION 4<BR><BR>OK TO INSTALL CORE PLUG AND REPAIR PLIES;[06] INSTALLED REPAIR PARTS USING BMS 8-201 TY IV LOT#1486456-1; AND BMS 5-28 TY 19 LOT#AK1KP5968K; VACUUM BAGGED; CHECKED FOR LEAKS USING PRESSURE GAGE ID:ATS2583 S/N:5432766772 IAW SRM 53-00-50-2R-6 PAR 3G(1);H(1).;[07] VERIFIED CORRECTIVE ACTION 6;[08] CURED REPAIR WITH THERMOMETER ID:ATS2208 S/N:43300740WS; UNBAGGED AND SANDED CORE PLUG SMOOTH TO SURFACE; FABRICATED LOWER SURFACE REPAIR PLIES<BR>FROM BMS 9-3H2 LOT#1475360-2 IAW SRM 53-00-50-2R-6 PARA 3I-K.<BR>OK TO INSTALL;