What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727D+18; BS 727E+3; BS 727E+6; BS 727E+10; BS 747+3; BS 747+12; BS 747+15. / [01] SRM 53-60-53-0I-2 IDENTIFICATION AND SRM 53-00-53-1A-2 ALLOWABLE DAMAGE ARE APPLICABLE<BR><BR>REMOVED CORROSION BY BLENDING FLOOR TO SIDEWALL SUPPORT UPPER SURFACE AT MULTIPLE AREAS PER SRM 51-10-02. MAXIMUM MATERIAL LOSS L=6.8'; W=0.9'; D=0.011'. ORIGINAL THICKNESS 0.040'; REMAINING THICKNESS 0.029'. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 FIGURE 103 DETAIL E.<BR>GAGE: ATS1672; S/N:65092939; DUE DATE 03/2023;[02] VERIFIED CORRECTIVE ACTION 1- BLEND IS OUT OF LIMITS;[03] LOCATED AND DRILLED FLOOR TO SIDEWALL SUPPORT FROM BS 727+4 TO BS 767; RBL 21 PER SRM 51-40-05 AND DWG# 146A7500. FROM EXTRUSION BAC1496-377#7075T62 LOT #1477731-1. OK TO TREAT AND PRIME;[04] VERIFIED CORRECTIVE ACTION 3.;[05] TREATED AND PRIMED FLOOR TO SIDEWALL SUPORT SECTION PER SRM 51-20-01 AND SOPM 20-41-02;[06] VERIFIED CORRECTIVE ACTION 5.;[07] UPDATED MEASUREMENTS;[08] FABRICATED FLOOR TO SIDEWALL SUPPORT FROM BS 727+4 TO BS 767; RBL 21 PER SRM 51-40-05 AND DWG# 146A7500. FROM EXTRUSION BAC1496-377#7075T62 LOT #1477731-1.;[09] VERIFIED CORRECTIVE ACTION 8.