What was found
CORROSION ON AFT CARGO BAY AFT LOWER BULKHEAD SUPPORT AT RBL 3 BS 947. / [01] VERIFIED APPLICABILITY OF SRM 51-10-02-0G-0;[02] NO ALLOWABLE DAMAGE LIMITS FOUND IN SRM FOR ACB AFT LOWER BULKHEAD SUPPORT; PART TO BE REPAIRED BY REPLACMENT PER SRM 51-10-02-0G-0;[03] VERIFIED CORRECTIVE ACTIONS 1-2. NO LIMITS IN SRM; PART TO BE REPLACED.;[04] LOCATED AND DRILLED HOLES IN NEW RECEIVED PART #149A8118U29 LOT# 1487879-1 PO# 863744 IAW SRM 51-40-05-0G-0 GENERAL - FASTENER HOLE SIZES AND DWG 149A8110 REV:-;[05] LOCATED AND DRILLED HOLES IN NEW RECEIVED PART #149A8118U29 LOT# 1487879-1 PO# 863744 IAW SRM 51-40-05-0G-0 GENERAL - FASTENER HOLE SIZES AND DWG 149A8110 REV:-<BR><BR>OK TO APPLY CHEMICAL CONVERSION AND PRIME BARE METAL;[06] VERIFIED UPDATED STATEMENT;[07] MEASUREMENTS;[08] MEASUREMENTS UPDATE;[09] VERIFIED CORRECTIVE ACTION ENTRIES 5-8. OK TO PRIME GIVEN.;[10] APPLIED CHEMICAL CONVERSION COATING; PRIME AND TOP COAT AT HOLES BARE METAL IAW AMM 51-21-41; AMM 51-21-72 AND AMM 51-21-73;[11] VERIFIED CORRECTIVE ACTION ENTRY 10. CARD COMPLETE.