What was found
CRACK ANGLE LOCATED AT BS 1016 BETWEEN S-2R AND S-2L UPPER FUSELAGE AT VERTICAL STABILIZER 2022-194752 / [01] TOOL USED: DIGITAL CALIPER 0-8? P/N: 500-197-30; S/N: A21144622 DUE DATE: 01-FEB-23;[02] REPLACED ANGLE LOCATED AT BS 1016 BETWEEN S-2R AND S-2L UPPER FUSELAGE AT VERTICAL STABILIZER IAW SRM 51-40-02 AND DWG 176A3001 REV:D. SEE INDIVIDUAL SIGN OFF BELOW;[03] REPLACED ANGLE LOCATED AT BS 1016 BETWEEN S-2R AND S-2L UPPER FUSELAGE AT VERTICAL STABILIZER IAW SRM 51-40-02 AND DWG 176A3001 REV:D. RII .SEE INDIVIDUAL SIGN OFF BELOW