What was found
AFT CARGO BAY LOWER ATTACH ANGLE COMMON TO SHIELD HAS AREAS OF CORROSION BS767 TO BS787 RBL21 WL156 / [01] EVALUATED CORROSION ON ATTACH ANGLE BS 767 TO 787 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTIONS STEP 1.;[03] REMOVED AFT CARGO BAY LOWER ATTACH ANGLE COMMON TO SHIELD; LOCATED; DRILLED; AND DEBURRED NEW ANGLE BS 767 TO BS 787 RBL21 WL156 PER SRM 51-40-02-0G-0; SRM 51-40-05-02-0 AND DWG 146A8123;[04] OK TO INSTALL ATTACH ANGLE;[05] OK TO INSTALL;[06] INSTALLED NEW ATTACH ANGLE SHIELD BS 767 TO 787 RBL21 WL156 SRM 51-40-02-0G-0; AND DWG 146A8123.;[07] RII INSPECTED;[08] INSPECTION COMPLETE