What was found
CORROSION CREASE BEAM FLOOR STRUCTURE LOCATED BS867 AT LEVEL LBL69 AND WL208.1 AT PASSENGER CABIN 2022-168789 / [01] TOOL USED: ULTRASONIC THICKNESS GAUGE P/N: 45MG; S/N: 130060401; DUE DATE: 26-JAN-23<BR>TOOL USED: EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 60009161631; DUE DATE: 03-DEC-22;[02] TOOL USED : EDDY CURRENT TOOL; P/N: NORTEC 500D; S/N: N500X12101V022233; DUE DATE: 02 JUN 22.;[03] PERFORMED PERMANENT REPAIR ON CREASE BEAM FLOOR STRUCTURE LOCATED BS867 AT LEVEL LBL69 AND WL208.1 AT PASSENGER CABIN IAW EA#22-153-01201-WIP1 & 22-153-01201-WIP2;[04] PERFORMED PERMANENT REPAIR ON CREASE BEAM FLOOR STRUCTURE LOCATED BS867 AT LEVEL LBL69 AND WL208.1 AT PASSENGER CABIN IAW EA#22-153-01201-WIP1 & 22-153-01201-WIP2. CERTIFIED RII;[05] PERFORMED PERMANENT REPAIR ON CREASE BEAM FLOOR STRUCTURE LOCATED BS867 AT LEVEL LBL69 AND WL208.1 AT PASSENGER CABIN IAW EA#22-153-01201-WIP1 & 22-153-01201-WIP2