What was found
CRACK IN RADIUS OF FRAME AT B.S. 312 JUST ABOVE FORWARD ENTRY DOOR CUT OUT. / [01] REMOVED DAMAGE AT FRAME RADIUS BS 312 JUST ABOVE FED CUT OUT I.A.W SRM 51-10-02-0G-0;[02] REMOVED DAMAGE AT FRAME RADIUS AREA OF .25 X .15 BS 312 JUST ABOVE FED CUT OUT I.A.W SRM 51-10-02-0G-0;[03] VERIFIED CORRECTIVE ACTIONS 1; 2.;[04] HFEC INSPECTED TRIMMED EDGE OF DAMAGE CUTOUT PER 737NDT PART 6 51-00-00 PROCEDURE 23. NO CRACKS FOUND. TOOL N500 IS000450.;[05] COMPLETED ALL STEPS;[06] VERIFIED ALL ITEMS AND EAS COMPLETED.