What was found
CORROSION ON FLOOR BEAM UPPER SURFACE STA 947.5 LBL 24 UNDER LAV MOUNT / [01] BLENDED SURFACE CORROSION ON UPPER CHORD OF FLOOR BEAM AT STA. 947.5; LBL 24? PER SRM 51-10-02. REMOVED .037? OF MATERIAL FROM UPPER SURFACE CHORD. DAMAGE REMOVAL OUT OF LIMITS PER SRM 53-70-51-1A-1.;11] REPAIRED CABIN FLOOR BEAM AT STA. 947.5; LBL 24 PER SRM 53-70-51-2R-8; ALTERNATIVE 3 AND EA 22-153-01109-WIP1; (TTG8Q00BUT7K) AND (TTG8Q00BXWHU);[12] VERIFIED CABIN FLOOR BEAM REPAIRED AT STA. 947.5; LBL 24 PER SRM 53-70-51-2R-8; ALTERNATIVE 3 AND EA 22-153-01109-WIP1; (TTG8Q00BUT7K) AND (TTG8Q00BXWHU) COMPLETE.