What was found
R/W T/E PANEL 661BB HAS SEVERAL PULLED FASTENER HOLES (MARKED) / FOUND DAMAGE TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 57-51-01-1A-1 PAR 4.B (5). <BR>REPAIR WILL BE ACCOMPLISHED IAW SRM 51-70-04-2R-9 AS DIRECTED PER SRM 57-51-01-2R-1 PAR 4.B (2) AND TABLE 202. FILLED DAMAGED FASTENER HOLES WITH RESIN BMS 8-301; CLASS 1; EA 9390; LOT# JH1GAA7833 AND CHOPPED FIBERS; LOT# 1437038-1 AND SET TO CURE. WORK ACCOMPLISHED IAW SRM 51-70-04-2R-9 PAR 4.D-F.;CURED SLURRY; SANDED SLURRY TO CONTOUR; PREPPED AND CLEANED REPAIR AREA; FABRICATED REPAIR PLIES FROM BMS 9-3 LOT 1475360-2 AREA IAW SRM 51-70-04-2R-9 PARA 4.F-J<BR><BR>HOT BONDER ID NCX000526 SN 12051216 DATE 10/2022; CORRECTION IN STEP 6 ( REMOVAL OF THE WORD 'AREA' )<BR><BR>CURED SLURRY; SANDED SLURRY TO CONTOUR; PREPPED AND CLEANED REPAIR AREA; FABRICATED REPAIR PLIES FROM BMS 9-3 LOT 1475360-2 IAW SRM 51-70-04-2R-9 PARA 4.F-J INSTALLED REPAIR PLIES USING BMS 8-301CL1 LOT#JH1GAA7833; VACUUM BAGGED CURED WITH SEALER RESIN 3501 LOT 1183B1111W SRM 51-70-04-2R-9 PARA 4.P APPLIED AND CURED CONDUCTIVE COATING; RESISTANCE CHECK 'GOOD' IAW AMM 51-21-71-370-801 PARA 3.D(2-4) AND 3.D(7)(A)<BR><BR>FLUKE 62 IR THERMOMETER ID ATS2209 SN 43300739WS DATE 10/2022<BR>FLUKE 77 MULTIMETER ID ATS1658 SN 34000350 DATE 03/2023<BR><BR>REFINISHED IAW AMM 51-21-99-300-802 PARA 3.C(1)(A-E);LOCATED; DRILLED AND COUNTERSUNK ALL FASTENER LOCATIONS FILLED FROM REPAIR IAW SRM 51-70-04-2R-9 PARA 4.N.