What was found
DOT#68-186 AFT PIT FLOOR SPLICE STRAP CORRODED STA 887 LBL 3 TO RBL 4 WL 156 / [01] VERIFIED REPLACEMENT PART AS P/N 149A9401-39; ITEM #650;IAW AIPC 53-42-11-26. A-TAG # WN15356.;[02] REMOVED DAMAGED PART FROM A/C IAW AMM 25-52-10-000-801.;[03] VERIFIED STEPS 1 AND 2;[04] LOCATED AND DRILLED FASTENER HOLES IAW SRM 51-40-05-0G-0. NEED OK TO CIC.;[05] VERIFIED STEP 4<BR>OK TO CIC;[06] APPLIED CIC IAW AMM 51-21-91-620-802.;[07] VERIFIED STEP 6;[08] OK TO INSTALL STRAP BS 887;[09] INSTALLED AFT PIT FLOOR SPLICE STRAP AT STA 887; IAW AMM 25-52-10-400-801.;[10] VERIFIED STEP 9<BR>AUDIT C/W