What was found
AFT PIT FWD SHIELD SUPPORT ANGLE AT STA 767+7 WL 155 RBL 22 HAS CORROSION ON UPPER SURFCE / [01] REMOVED CORRODED FWD SHIELD SUPPORT ANGLE BS 767-787 RBL 22 IAW SRM 51-40-02-0G-0;[02] VERIFIED NEW FWD SHIELD SUPPORT ANGLE BS 767-787 RBL 22 IAW DWG 146A0081 REV A P/N 146A8125-53 ATAG WN15434;[03] VERIFIED NEW PART;[04] LOCATED AND DRILLED FWD SHIELD IAW SRM 51-40-05-0G-0 DWG 146A0081 REV A;[05] EDIT TO ITEM 4. LOCATED AND DRILLED FWD SHIELD SUPPORT ANGLE IAW SRM 51-40-05-0G-0 DWG 146A0081 REV A;[06] VERIFIED STEPS 4 AND 5<BR>OK TO INSTALL<BR>OK TO CIC;[07] INSTALLED NEW FWD SHIELD SUPPORT ANGLE IAW SRM 51-40-02-0G-0 DWG 146A0081 REV A;[08] REMOVED AND REPLACED AFT PIT FWD SHIELD SUPPORT ANGLE AT STA 767-787 RBL 22 IAW SRM 51-40-02-0G-0 AND DWG 146A0081 REV A;[09] VERIFIED STEPS 7 AND 8 <BR>AUDIT C/W