What was found
FWD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT PLATE HAD MULTIPLE AREAS OF CORROSION FROM BS 500A - 500I, RBL24, WL156. FOUND DEEPEST LOCATION AT BS 500C+10, RBL 24, WL 156. FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMEROUS 1'X1' AREAS, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED RT FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY IAW SRM 51-40-02-0G-0. FABRICATED FWD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT PLATE WITH A SPLICE IAW SRM 53-00-53-2R-5 REPAIR 5 . FABRICATED 2 TAPERED FILLERS AND SPLICE SIDEPLATE IAW SRM 53-00-53-2R-5 REPAIR 5 AND 22-153-01373 - WIP1. THE DAMAGE WAS REPAIRED IAW SRM 53-00-53-2R-5 (REPAIR 5) AND EA 22-153-01373'.