What was found
FORWARD CARGO BAY SHIELD AFT OF DOOR HAS CORROSION BS 500+10 RBL 24 WL 156 / [01] EVALUATED CORROSION ON SHIELD BS 500+10 RBL 24 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED FCB SHIELD BS 492 TO BS 500A; RBL 24; WL 156. PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW FCB SHIELD BS 492 TO BS 500A; RBL 24; WL 156 PER DWG 143A0080 AND SRM 51-40-05-0G-0. OK TO INSTALL.;[05] VERIFIED CORRECTIVE ACTION 4; OK TO INSTALL GIVEN.;[06] BEGAN INSTALLING NEW FCB SHIELD BS 492 TO BS 500A; RBL 24; WL 156 PER DWG 143A0080 AND SRM 51-40-02-0G-0.;[07] INSTALLED NEW FCB SHIELD BS 492 TO BS 500A; RBL 24; WL 156 PER DWG 143A0080 AND SRM 51-40-02-0G-0.;[08] VERIFIED CORRECTIVE ACTION ENTRY 7.;[09] VERIFIED CARD COMPLETE.