What was found
AFT CARGO BAY SUB THRESHOLD WEB HAS CORROSION BS 787+17 TO 807+6 RBL 26 WL 158 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND THE DEEPEST LOCATION TO BE AT BS 787+18 RBL 26 WL 158; FOUND 0.015 REMOVED FROM ORIG 0.045 IN NUMEROUS 1'X1' AREAS FOUND TO BE OUT OF LIMITS PER SRM 53-60-15-1A-1 USING DIAL DEPTH GAUGE ATS 1225;[02] VERIFIED CORRECTIVE ACTION ENTRY 1.;[03] REMOVED AFT CARGO BAY CORROSION DAMAGED SUB THRESHOLD WEB FROM BS794 TO BS 847 RBL 20 TO RBL 28 WL 158 IAW SRM 51-40-02-0G-0;[04] BEGAN LOCATING AND DRILLING FASTENER HOLES PER SRM 51-40-05-0G-0. DWG 146A8340.;[05] COMPLETED LOCATING AND DRILLING FASTENER HOLES; INSTALLED NUTPLATES PER SRM 51-40-05-0G-0; SRM 51-40-02-0G-0; DRAWING 146A8340. OK TO INSTALL NEW SUB THRESHOLD WEB.;[06] VERIFIED CORRECTIVE ACTION 5; OK TO INSTALL GIVEN;[07] INSTALLED AFT CARGO BAY SUB THRESHOLD WEB PER SRM 51-40-02-0G-0; DWG 146A8340.;[08] VERIFIED CORRECTIVE ACTION ENTRY 7.;[09] VERIFIED CARD COMPLETE.