What was found
AFT CARGO BAY SHIELD FORWARD OF DOOR HAS CORROSION BS 767+4 RBL 23 WL 156 / [01] EVALUATED CORROSION ON ANGLE BS 767+4 RBL 23 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] CORRECTION; CORROSION EVALUATION WAS ON SHIELD; NOT ANGLE;[03] INSPECTED & VERIFIED CORRECTIVE ACTION ITEMS 1 & 2.;[04] REMOVED AFT CARGO BAY SHIELD FORWARD BS767- BS793 RBL23 WL156 PER SRM 51-40-02-0G-0;[05] LOCATED AND DRILLED NEW AFT CARGO BAY SHIELD FORWARD BS 767- BS793 RBL23 WL156 PER SRM 51-40-05-0G-0 AND DWG 146A0081<BR>OK TO INSTALL;[06] VERIFIED STEPS 1-5;[07] INSTALLED NEW AFT CARGO BAY SHIELD FORWARD BS 767- BS793 RBL23 WL156 PER SRM 51-40-02-0G-0 AND DWG 146A0081;[08] VERIFIED CORRECTIVE ACTION 7.