What was found
CRACKED INTERCOSTAL STA 344-360; BL0; WL 208. / [01] REMOVED CRACKED INTERCOSTAL AT BS344-360; BL0; WL208 IAW SRM 51-40-02. ALSO; UPDATED MEASUREMENTS.;[02] LOCATED AND DRILLED NEW INTERCOSTAL STA 344-360; BL0; WL 208 PER SRM 51-40-02-0G-0; DWG# 141A5400. OK TO INSTALL.;[03] VERIFIED CORRECTIVE ACTION 2.;[04] INSTALLED NEW INTERCOSTAL STA 344-360; BL0; WL 208 PER SRM 51-40-02-0G-0; DWG# 141A5400.;[05] VERIFIED CORRECTIVE ACTION 4. VERIFIED INSTALLATION;[06] VERIFIED ALL STEPS COMPLETE.