What was found
AFT CARGO BAY LAV ENCLOSURE ANGLE IS CRACKED BS 867 LBL 11 WL 164 / [01] REMOVED AFT BAY LAV ENCLOSURE ANGLE BS 867 LBL 11 WL 164 PER SRM 51-40-02-0G-0.;[02] LOCATED; DRILLED; AND DEBURRED NEW ENCLOSURE ANGLE BS 867 LBL WL 164 PER SRM 51-40-05-0G-0; DWG 149A8102 AND DWG 149A8104; OK TO INSTALL.;[03] OK TO INSTALL GIVEN.;[04] INSTALLED NEW ENCLOSURE ANGLE BS BS 867 LBL 11 WL 164 PER SRM 51-40-02-0G-0; DWG 149A8102 AND DWG 149A8104;[05] VERIFIED CORRECTIVE ACTION 4.