What was found
PASS. CABIN WET AREA FLOOR PANEL 221GF IS MISSING TAB PIECE FROM FWD O/B EDGE / [01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>REMOVED 1EA THROUGH INSERT TO FACILITATE REPAIR IAW SRM 53-00-50-2R-6 PARA 3B.<BR>REMOVED DAMAGE AT FWD O/B END; CLEANED REPAIR AREA; FABRICATED CORE PLUG USING BMS 8-124 TY5<BR>GR9 CL4 LOT#1287137 AND FABRICATED UPPER SURFACE REPAIR PLIES USING BMS 9-3H2 LOT#1475360-2<BR>IAW SRM 53-00-50-2R-6 PARA 3C-G.<BR>OK TO INSTALL REPAIR PARTS.;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-6.;[07] FABRICATED LOWER SURFACE REPAIR PLIES FROM BMS 9-3H2 LOT#1475360-2 IAW SRM 53-00-50-2R-6 PARA 3K.<BR>OK TO INSTALL REPAIR PLIES.;[08] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 6 AND 7. OKAY TO INSTALL REPAIR PLIES PER SRM 53-00-50-2R-6.;[09] INSTALLED LOWER REPAIR PLIES USING BMS 8-201TY4 LOT#AK1KP9161K; VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2438 S/N:UNKNOWN IAW SRM 53-00-50-2R-6 PARA 3K-L.;[10] INSPECTED AND VERIFIED CORRECTIVE ACTION 9. 5X5 LEAK CHECK PASSED PER SRM 53-00-50-2R-6.