What was found
L/H BS663 VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT LBL8; WL167.68 / REMOVED DAMAGED SECTION OF BS663 LH VAPOR BARRIER UPPER ATTACH ANGLE FROM LBL8-LBL20 WL167.68 IAW SRM 57-10-10-2R-5.PERFORM A DETAILED INSPECTION OF THE REPAIR AREA AND THE UNDERLYING STRUCTURE TO MAKE SURE THAT THERE IS NO DAMAGE WITHIN THE REPAIR AREA IAW SRM 57-10-10-2R-5. ACCOMPLISHED A DVI THE REPAIR AREA AND UNDERLYING STRUCTURE IAW SRM 57-10-10-2R-5 STEP 4.D. NO DAMAGE FOUND WITHIN THE REPAIR AREA;VERIFIED MEASUREMENT TABLE;PERFORM AN OPEN HOLE HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION FOR ALL INITIAL FASTENER HOLES IN THE REPAIR AREA TO MAKE SURE THERE IS NO DAMAGE IAW SRM 57-10-10-2R-5. APPLIED CHEMICAL CONVERSION COATING AND PRIMERED REPAIR PARTS @ BS663 LBL8-LBL20 WL167.68 IAW SRM 57-10-10-2R-5.INSTALLED REPAIR PARTS @ BS663 VAPOR BARRIER UPPER ATTACH ANGLE LBL8-LBL20 WL167.8 IAW SRM 57-10-10-2R-5.