What was found
FLOORPANEL 221BF HAS BROKEN TAB AFT OUTBD EDGE. IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4F.DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>REMOVED 1EA THROUGH INSERT TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3B.REMOVED DAMAGED PLIES ON TANG AREA AND CLEANED IAW SRM 53-00-50-2R-1 PARA 3C-E. INSTALLED REPAIR PLIES USING BMS 8-201TY4 LOT#1486957-3; VACUUM BAGGED; LEAK CHECK GOOD. 5X5 LEAK CHECK PASSED PER SRM 53-00-50-2R-1. CURED REPAIR PLIES; UNBAGGED AND TRIMMED EXCESS MATERIAL INSTALLED 1EA PREVIOUSLY REMOVED INSERT USING BMS 5-107 LOT#AK0KP9324K IAW SRM 53-00-50-2R-1 PARA 3M;N.