What was found
CORROSION ON FSD THRESHOLD SUPPORT ANGLE BS312+14 RBL 5 WL 209 .VERIFIED EFFECTIVITY OF SRM 53-10-15-0I-2 FOR STRUCTURE ID AND SRM 53-10-15-1A-2 FOR ALLOWABLE DAMAGE.; UPON FURTHER INVESTIGATION FOUND DAMAGE TO BE LOCATED AT BS 312+14; RBL 57; WL 209. REMOVED FSD THRESHOLD SUPPORT ANGLE PER SRM 51-40-02.;LOCATED AND DRILLED NEW FSD THRESHOLD SUPPORT ANGLE PER SRM 51-40-05 AND DWG#141A8310. AND REQUEST OK TO INSTALL.;THE FSD THRESHOLD ANGLE.;INSTALLED NEW FSD THRESHOLD ANGLE PER SRM 51-40-02 AND DWG#141A8310..