What was found
CORROSION ON FWD CARGO BAY FWD DOOR SHIELD AT RBL 25 BS 420+9; BS 420+12. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED MEASUREMENT TABLE AND CORRECTIVE ACTION 1.;[03] REMOVED FWD CARGO BAY FWD DOOR SHIELD AT RBL 25 BS 420- BS 440 PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW SHIELD AT RBL 25 BS 420- BS 440 PER SRM 51-40-05-0G-0 AND DWG 143A0080.<BR>OK TO INSTALL.;[05] VERIFIED CORRECTIVE ACTION STEPS 3 AND 4. VERIFIED OK TO INSTALL.;[06] INSTALLED NEW SHIELD AT BS 420- BS 440 RBL 25 PER SRM 51-40-02-0G-0 AND DWG 143A0080.;[07] VERIFIED CORRECTIVE ACTION STEP 6.;[08] VERIFIED MEASUREMENT TABLE AND TASK COMPLETE.