What was found
CORROSION ON FWD CARGO BAY AFT DOOR SHIELD AT RBL 24 BS 500+3; BS 500+7; BS 500+16. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED MEASUREMENT TABLE AND CORRECTIVE ACTION 1.;[03] REMOVED FCB CARGO BAY AFT DOOR SHIELD AT RBL 24 BS 492- BS 500A PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW SHIELD AT BS 492- BS 500A RBL 24 PER SRM 51-40-05-0G-0 AND DWG 143A0080.<BR>OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4.;[06] INSTALLED SHIELD AT BS 492- BS 500A RBL 24 PER SRM 51-40-02-0G-0 AND DWG 143A0080.;[07] VERIFIED CORRECTIVE ACTION 6.;[08] WORKSCOPE COMPLETE