What was found
SUPPORT ANGLE AT VAPOR BARRIER LH STA 663 CRACKED / [01] LOCATED AND DRILLED NEW SUPPORT ANGLE AT VAPOR BARRIER L/H STA 663 PER REF B737-700 SRM51-40-05-0G-0.;[02] VERIFIED STEP 1. OK TO TREAT AND PRIMER.;[03] TREATED AND PRIMED NEW HOLES ON NEW ANGLE PER REF B737-700 AMM 51-21-41-370-802 AND AMM 51-21-72-370-804.;[04] LOCATED AND DRILLED NEW SUPPORT ANGLE;TREATED AND PRIMED NEW HOLES AT VAPOR BARRIER L/H STA 663 PER REF B737-700 SRM51-40-05-0G-0.;[05] LOCATED AND DRILLED NEW SUPPORT ANGLE;TREATED AND PRIMED NEW HOLES AT VAPOR BARRIER L/H STA 663; INSTALLATION OF THIS SUPPORT ANGLE IS ACCOMPLISHED ON CARD (TTG8Q00CGDYE) PER REF B737-700 SRM51-40-05-0G-0.;[06] VERIFIED STEPS 3;4 AND 5.