What was found
FILLET FAIRING 193B HAS SEVERAL ELONGATED FASTENER HOLES / [01] PERFORMED VISUAL INSPECTION AND TAP TEST AT FAIRING PANEL #193B FOUND SEVEN ELONGATED FASTENER HOLES AS PER B737 NTM 51-05-01;[02] VERIFIED STEP 1;[03] PREPARED DAMAGED AREA TO APPLY REPAIR AT PANEL 193B PER B737SRM 51-70-04-2R-0;[04] VERIFIED PREPARED PANEL<BR>OK TO REPAIR;[05] REPAIRED PANEL 193B ON DAMAGED AREA PER B737SRM 51-70-04-2R-9 AND PERFORMED TAP TEST AROUND THE REPAIR NO DELAMINATION FOUND PER B737 NTM 51-05-01 MATERIAL USED RESIN EY 3804 PO#1753794 AND FIBERGLASS PO#1690463;[06] VERIFIED REPAIR;[07] APPLIED TOPCOAT ON PANEL 193B REF B 737 AMM 51-21-73-370-803;[08] PANEL 193B WILL BE INSTALLED ON CARD: TTG8Q00BAM74.