What was found
CRACKED LOWER L/H COMPOSITE BULKHEAD AT BS663 LBL32 WL156. IDENTIFIED LOWER L/H COMPOSITE BULKHEAD AT BS663 LBL32 WL156 IAW SRM 57-10-10-0I-2 FIGURE 2; SHEET 1; TABLE 2; ITEM 4.DAMAGE NOTED IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 57-10-10-1A-2 PAR 4D(1).REPAIR TO BE ACCOMPLISHED IAW SRM 51-70-04-2R-10 PER SRM 57-10-10-2R-2 PAR 1C. STOP DRILLED CRACK; REMOVED DAMAGE FROM BOTH FWD AND AFT FACE SHEETS; CLEANED IAW SRM 51-70-04-2R-10 PAR 4A-C. VALIDATED REPAIR PER SRM 51-70-04-2R-10; FABRICATED REPAIR PLIES OUT OF BMS 9-3 ST 1581 LOT#1393735-8 IAW SRM 51-70-04-2R-10 PAR 4D. INSTALLED REPAIR PLIES USING BMS 8-301 CL1 GR1 LOT#JH1GAA7833; VACUUM BAGGED; UNBAGGED AND LIGHTLY SANDED REPAIR PLIES IAW SRM 51-70-04-2R-10 PARA 4F;HREFINISHED REPAIR AREAS IAW SRM 51-70-04-2R-10 PARA 4.H;