What was found
CRACK IN RADIUS OF FRAME AT B.S. 312 JUST ABOVE FORWARD ENTRY DOOR CUT OUT. / [01] TRIMMED OUT DAMAGE AT STA 312 FRAME LBL32 WL282 IAW SRM 51-10-02-0G-0;[02] SRM 53-10-15-1A-1 IS APPLICABLE FOR ALLOWABLE DAMAGE.;[03] TRIMMED .250 FROM EDGE OF FRAME. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-1.;[04] REQUEST NDI VERIFY TRIM OUT IS CRACK FREE IAW SRM 51-10-02-0G-0 PENDING ENGINEERING.;[05] VERIFIED CORRECTIVE ACTION 1-3;[06] HFEC INSPECTED CUT EDGE IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>NO CRACKS NOTED.<BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS1465 CAL DUE: 08/22;[07] COMPLETE;[08] COMPLETE