What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727C+10; BS 727D+6; BS 727D+10; BS 727D+14; BS 727E+2; BS 727E+6; BS 727E+10; BS 727E+18. / [01] REMOVED CORROSION FROM R/H ACB FLOOR TO SIDEWALL SUPPORT AT BS727D+10 MEASURED 1.9"L X 0.9"W AND 0,004"DEEP, ORIGINAL THICKNESS OF 0.040" FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 REMOVED CORROSION FROM R/H ACB FLOOR TO SIDEWALL SUPPORT AT BS727E+2 MEASURED 2.1"L X 0.9"W AND 0,021"DEEP, ORIGINAL THICKNESS OF 0.040" FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 REMOVED CORROSION FROM R/H ACB FLOOR TO SIDEWALL SUPPORT AT BS727E+10 MEASURED 2.5"L X 1.1"W AND 0,015"DEEP, ORIGINAL THICKNESS OF 0.040" FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 REMOVED CORROSION FROM R/H ACB FLOOR TO SIDEWALL SUPPORT AT BS727E+18 MEASURED 1"L X 0.8"W AND 0,010"DEEP, ORIGINAL THICKNESS OF 0.040" FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 CAL ID PIN POINT DEPTH GAUGE ATS1225 S/N UNKNOWN DUE 07/2022 [03] UPDATED MEASUREMENTS;[04] VERIFIED CORRECTIVE ACTION 1;[05] WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q00C8935 (FUSE 5104);[06] WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q00C8935;[07] VERIFIED CORRECTIVE ACTION #5<BR>WORK TO BE COMPLETED ON CUSTOMER CARD TTG8Q00C8935 (FUSE 5104)