What was found
AFT CARGO BAY SHIELD HAS CORROSION BS 847+10 RBL 23 WL 164 / [01] EVALUATED CORROSION ON SHIELD BS 847+10 RBL 23 WL 164; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION ENTRY 1. OUT OF LIMITS.;[03] REMOVED ACB AFT SHIELD BS847 TO BS867; RBL 23; WL 164. PER SRM 51-40-02-0G-0.;[04] BEGAN LOCATING AND DRILLING NEW ACB AFT SHIELD BS847 TO BS867; RBL 23; WL 164. PER DWG 146A0081 AND SRM 51-40-05-0G-0.;[05] LOCATED AND DRILLED NEW ACB AFT SHIELD BS847 TO BS867; RBL 23; WL 164. PER DWG 146A0081 AND SRM 51-40-05-0G-0. OK TO INSTALL.;[06] VERIFIED CORRECTIVE ACTIONS STEP 5; OK TO INSTALL GIVEN.;[07] INSTALLED NEW ACB AFT SHIELD BS847 TO BS867; RBL 23; WL 164. PER DWG 146A0081 AND SRM 51-40-02-0G-0.;[08] VERIFIED CORRECTIVE ACTIONS STEP 7.