What was found
CRACKED INTERCOSTAL AT FWD PASSENGER CABIN BS317 RBL31 WL208. / [01] VERIFIED APPLICABILITY AS PER SRM 53-10-51-1A-1.<BR><BR>CRACK WAS FOUND OUT OF LIMIT DUE DISTANCE FROM HOLE; NO PERMITTED; IAW SRM 53-10-51-1A-1 STEP 4.B(1)(A); FIG.105.<BR><BR>LOCATED AND DRILLED NEW INTERCOSTAL P/N: 141A5410-12; IAW SRM 51-40-05 AND DWG 141A5400.;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT TABLE.;[03] INSTALLED NEW INTERCOSTAL AT BS312 - BS328; RBL31; IAW SRM 51-40-02 AND DWG. 141A5400;[04] VERIFIED CORRECTIVE ACTION #3