What was found
GROUND POWER DOOR CUT-OUT INTERNAL DOUBLER CRACKED ON AFT EDGE / [01] CUT OUT DAMAGED PORTION OF EGPR SURROUND DOUBLER ON LOWER AFT CORNER; ACCOMPLISHED 10X INSP OF TRIM OUT; FOUND NO DEFECTS. WORK ACCOMPLISHED IAW SRM 53-10-15-2R.;[02] HFEC IAW B737 NDT PART 6; 51-00-00 PROC 23. NO DEFECTS NOTED. TOOL#31823; DUE 23DEC22;[03] VERIFIED ITEM 1;[04] ACCOMPLISHED .040' INSURANCE CUT ON TRIM OUT IAW SRM 53-10-15-2R.;[05] FOUND EXISTING ZONE 1 REPAIR DOUBLER AND RUBBING STRIP TO BE IN COMPLIANCE WITH SRM 53-10-15-2R REPAIR 4.;[06] VERIFIED ITEMS 4 AND 5; OK TO TREAT AND PRIME;[07] APPLIED ALODINE AND PRIMED TRIMED EDGE IAW SRM 53-10-15-2R.;[08] STEP 7 OK; OK TO PAINT;[09] APPLIED FINISH COAT TO TRIMMED AREA IAW SRM 53-10-15-2R. JOB IS COMPLETE.;[10] C/W