What was found
CRACK IN VERTICAL L ANGLE BS 692 RBL 0.5 WL 206.5 / [01] REMOVED ANGLE AT VERTICAL ANGLE BS 692 RBL .5 WL 206.5 PER SRM 51-40-02;[02] VERIFIED THE APPLICABILITY OF SRM 51-40-02-0G-0;[03] FORMED NEW VERTICAL 'L' ANGLE BS 692 RBL 0.5 WL206.5 MATERIAL USED 7075T0 ; 0.050' CLAD LOT # 1474582-1 IAW DWG # 273A9112 SENT TO O.S.S FOR HEAT TREAT TO T73 .;[04] VERIFIED CORRECTIVE ACTION #3;[05] RECEIVED THE NEW VERTICAL 'L' ANGLE BS 692 RBL 0.5 WL206.5 FROM O.S.S AFTER BEING HEAT TREATED TO T73 AND DYE PENETRANT INSPECTED ON CUSTOMER R/O # 868549-SWA ; LOCATED AND DRILLED THE NEW ANGLE IAW SRM 51-40-05 ; OK TO TREAT AND PRIME;[06] VERIFIED CORRECTIVE ACTION #5.<BR>VERIFIED OK TO TREAT AND PRIME.;[07] APPLIED A CHEMICAL CONVERSION COATING AND PRIMER TO THE NEW 'L' ANGLE IAW SRM 51-20-01 AND SOPM 20-44-04 ; OK TO INSTALL;[08] VERIFIED CORRECTIVE ACTION #7.<BR>VERIFIED OK TO INSTALL REPAIR PARTS.;[09] INSTALLED THE NEW VERTICAL 'L' ANGLE BS 692 RBL 0.5 WL206.5 IAW SRM 51-40-02 AND DWG # 273A9110;[10] VERIFIED CORRECTIVE ACTION #9.