What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS947; LBL6; LBL9. / [01] REMOVED AFT CARGO BAY FLOOR TO BULKHEAD SUPPORT ANGLE BS 947 LBL9 TO RBL 20 IAW SRM 51-40-02-0G-0;[02] EVALUATE DAMAGE: CORROSION AT ACB ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT BS 947 ; LBL6; LBL .9 FOUND TO BE OUT OF LIMIT DUE TO NO HAVE ENTRIES BY ALLOWABLE DAMAGE IN SRM. PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR-9;[03] RECEIVED ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS 947 LBL 6 TO RBL 21 ITEM 149A8118-29 PO#869044. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 149A8118;[04] OK TO INSTALL AFT CARGO BAY AFT BULKHEAD LOWER SUPPORT ANGLE;[05] VERIFIED CORRECTIVE ACTION #2; 3; 4<BR>VERIFIED MEASUREMENTS;[06] INSTALLED AFT CARGO BAY AFT BULKHEAD LOWER FLOOR SUPPORT ANGLE BS 947 IAW SRM 51-40-02-0G-0 AND DWG# 149A8117 REVB-C;[07] VERIFIED CORRECTIVE ACTION #6