What was found
AFT CARGO DOOR CUTOUT STA 787+8 RBL 20' FLOOR SUPPORT LOWER STRAP CORRODED AROUND NUTPLATE. REMOVED CORROSION IAW AMM 51-00-53-201. PERFORMED UT THICKNESS INSP ON REWORKED AREA IAW NDT P4 51-00-00 PROC.3 ; MIN THK. NOTED 0.029'. ORIGINAL MATERIAL: 0.040'; REMAINING MATERIAL: 0.029'; MATERIAL LOSS; 0.011'. FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1. FABRICATED AFT CARGO DOOR CUTOUT BS 787+8 RBL 20' FLOOR SUPPORT LOWER STRAP IAW DRAWING 146A8128. TREATED AND PRIMED FABRICATED AFT CARGO DOOR CUTOUT FLOOR SUPPORT LOWER STRAP IAW AMM 51-00-59-201 & 51-21-72-370-801. INSTALLED AFT CARGO DOOR CUT OUT FLOOR SUPPORT LOWER STRAP IAW SRM 51-40-02-0G-0.