What was found
CORROSION ON AFT CARGO BAY INTERCOSTAL ANGLE BELOW SHIELD BS 767+5 RBL 22 WL 156<[01] EVALUATED CORROSION ON ANGLE BS 767+5 RBL 22 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION #1;[03] REMOVED ACB INTERCOSTAL ANGLE BELOW SHIELD BS 767-787; RBL 22; WL 156 IAW SRM 51-40-02-0G-0.;[04] LOCATED AND DRILLED NEW AFT CARGO BAY INTERCOSTAL ANGLE BELOW SHIELD BS 767-787; RBL 22; WL 156 IAW SRM 51-40-05-0G-0 AND DWG 146A8123. INSTALLED NEW AFT CARGO BAY INTERCOSTAL ANGLE BELOW SHIELD BS 767-787; RBL 22; WL 156 IAW SRM 51-40-02-0G-0 AND DWG 146A8123.