What was found
CORROSION ON AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT BS 727F+16 TO BS 767 RBL 23 WL 156. REMOVED ACB FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0; SRM 53-00-53-2R-5. FABRICATED; LOCATED AND APPLIED CHEMICAL CONVERSION COATING TO ACB FLOOR TO SIDEWALL SUPPORT AND SPLICE REPAIR IAW SRM 51-40-05-0G AND DWG 146A7500; SRM 53-00-53-2R-5; AMM 51-21-41-370-802. APPLIED PRIMER TO SIDEWALL SUPPORT AND REPAIR PARTS PER AMM 51-21-72-370-804. APPLIED PRIMER TO ACB R/H FLOOR TO SIDEWALL SUPPORT AND REPAIR PARTS IAW AMM 51-21-72-370-804. INSTALLED ACB FLOOR TO SIDEWALL SUPPORT & SPLICE REPAIR IAW SRM 51-40-02-0G AND DWG 146A7500; SRM 53-00-53-2R-5.