What was found
FWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS 500A TO BS500I RBL23 WL156<[01] EVALUATED CORROSION AT ALL LOCATIONS OF FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 500D+10 RBL 23 WL 156 IN NUMEROUS 1'X1' AREAS; FOUND 0.015 REMOVED FROM ORIG 0.040; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2678 DUE 04/2023;[02] VERIFIED CORRECTIVE ACTION ENTRY 1. OUT OF LIMITS;[13] ' THE DAMAGE WAS REPAIRED PER 737-800 SRM 53-00-53-2R-5 (REPAIR 5) AND EA 22-153-01711'.;[14] VERIFIED CORRECTIVE ACTION ITEM 13; AND MEASUREMENT FIELDS; JOB COMPLETE