What was found
FWD CARGO R/H TRANSITION ANGLE AT STA 500D +2 RBL25 SHOWS SIGNS OF CORROSION. / [01] BLENDED OUT CORROSION AT FWD CARGO R/H TRANSITION ANGLE STA 500D + 2? PER SRM 51-10-02. MEASURED AND FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL D.;[02] REMOVED R/H TRANSITION ANGLE FOR REPLACEMENT FROM STA 500 TO 500I PER SRM 51-40-02;[03] FABRICATED REPAIR SPLICE PARTS PER SRM 53-00-53-2R-5.;[04] INSTALLED BONDED NUT PLATES ON REPAIR PARTS PER SRM 51-40-10-2R-0 AT 0900 UTC TIME;[05] FABRICATED SPLICE SIDEPLATE PER EA 22-153-01673-WIP1.;[06] VERIFIED <BR>FABRICATED SPLICE SIDEPLATE PER EA 22-153-01673-WIP1.;[07] FABRICATED TWO EA SHIMS PER EA 22-153-01673-WIP1. FIG 1-1;[08] VERIFIED C/W 7. RAY LINCH (TECHNICIAN); 10-JUN-2022 04:47 UTC<BR>FABRICATED TWO EA SHIMS PER EA 22-153-01673-WIP1. FIG 1-1;[09] OK TO INSTALL REPAIR TRANSITION ANGLE FROM STA. 500 TO STA. 500I.;[10] REPAIRED PER EA-22-153-01673 AND SRM 53-00-53-2R-5.;[11] C/W INSPECTION OF TRANSITION ANGLE INSTALL;[12] C/W INSPECTION OF TRANSITION ANGLE INSTALL;[13] REPLACED 3 EA DISBONDED NUTPLATES AT R/H TRANSITION ANGLE PER SRM 51-40-10-2R-0. TIME APPLIED 02:50 UTC;[14] UPDATED TOOL INFO AND PUSH TESTED NUTPLATES PER SRM 51-40-10-2R-0.;[15] UPDATED MEASUREMENTS.;[16] CERTIFIED.;[17] REPAIRED RH TRANSITION ANGLE STA 500D+2; RBL25 PER EA 22-153-01673-WIP1 AND SRM 53-00-53-2R-5..;[18] REPAIRED RH TRANSITION ANGLE STA 500D+2; RBL25 PER EA 22-153-01673-WIP1 AND SRM 53-00-53-2R-5.