What was found
FWD CARGO L/H ZEE ANGLE WITH CORROSION SPOT AT STA 500A+2' AND LBL-22 AND ABOUT WL 158 / [01] STARTED REMOVING CORROSION AT FWD CARGO LT. SIDE ZEE ANGLE STA 500A + 2. FOUND CORROSION OUT LIMITS; ORIGINAL MAT. 0.040; MAT. LOSS 0.025; MAT. REMAINING 0.015 IN REF SRM 51-10-02-OG-0 AND SRM 53-00-53-1A-2;[02] RECEIVED NEW Z CHANNEL P/N:143A7501-183; THIS PART WILL BE INSTALLED IN JOB CARD TTG8Q004ADJB;[03] C/W;[04] VERIFIED STEP 1 AND 2