What was found
CAPT #3 WINDOW FRAME CRACKED AT FWD LWR #9 HOLE EXTENDING FROM FASTENER HOLE TO BOTH SIDES OF FRAME VERIFIED HFEC 51-00-00 PROCEDURE 23 / [01] ACCOMPLISHED HFEC AROUND 8 EACH FASTENER HOLES ABOVE CRACKED AREA IAW B737 NDT P6 51-00-00 P23 NO CRACKS NOTED<BR><BR>ACCOMPLISHED OPEN HOLE HFEC AT 8 EACH FASTENER HOLES ABOVE CRACKED AREA IAW B737 NDT P6 51-00-00 P16 NO CRACKS NOTED<BR><BR>ACCOMPLISHED COUNTERSINK HFEC AT 8 EACH FASTENER HOLES ABOVE CRACKED AREA IAW B737 NDT P6 53-30-00 P3 NO CRACKS NOTED<BR><BR>TOOL 36303 DUE 13APR23;[02] ACCOMPLISHED DVI OF DAMAGED AREA FOR LOOSE OR MISSING FASTENERS; CRACKS; CORROSION; WEAR; AND STRUCTURAL CONDITION IAW SRM 51-10-02-0G-0. NO ADDITIONAL DEFECTS NOTED.;[03] VERIFIED STEP 2 C/W<BR>ACCOMPLISHED DVI OF DAMAGED AREA FOR LOOSE OR MISSING FASTENERS; CRACKS; CORROSION; WEAR; AND STRUCTURAL CONDITION IAW SRM 51-10-02-0G-0. NO ADDITIONAL DEFECTS NOTED.