What was found
CORRODED ANGLE ASSY; LOCATED AT APU COMPT CUTOUT LH SIDE; LBL 22; BS 1092 TO BS 1135 / [01] ADDED MEASUREMENTS.;[02] PARTIAL UPDATE TO STEP 1;[03] PARTIAL UPDATE TO STEPS 2-3.;[04] PARTIAL UPDATE TO STEPS 4-6;[05] PARTIAL UPDATE TO STEP 7.;[06] STEPS 2-7 PARTIAL UPDATED.;[07] ANGLE WAS FOUND TO BE OUT OF LIMITS; WILL BE REPAIRED BY REPLACE PART IAW SRM 51-10-02 PAR. 9.<BR><BR>RECEIVED NEW ANGLE P/N: 148A8615-54 ; LOT: 1493960-1 ; P.O/N: 871423/1.;[08] RECEIVED LOCATED AND DRILLED NEW ANGLE ASSY LOCATED FROM B/S 1088 TO B/S 1156 AT APU COMPT CUT OUT L/H SIDE LBL22 ; P/N: 148A8615-54; LOT#1493960-1 IAW SRM 51-40-05 AND DWG 148A8600 REV:- DWG 148A1670 REV:B;[09] OK TO INSTALL NEW ASSY ANGLE;[10] VERIFIED CORRECTIVE ACTIONS 7; 8 AND 9. OK TO INSTALL GIVEN..;[11] INSTALLED NEW ANGLE ASSY LOCATED FROM B/S 1088 TO B/S 1156 AT APU COMPT CUT OUT L/H SIDE LBL22 IAW SRM 51-40-02 AND DWG 148A8600 REV:-;[12] VERIFIED CORRECTIVE ACTION 11 AND MEASUREMENT TABLE.;[13] WORKSCOPE COMPLETE.