What was found
CRACK ANGLE LOCATED AT LEVEL BS1016 AND INTERNAL CAVITY ACCESS PANEL 323BL AT VERTICAL STABILIZER 2022-316839 / [01] REPLACED ANGLE LOCATED AT LEVEL BS1016 AND INTERNAL CAVITY ACCESS PANEL 323BL AT VERTICAL STABILIZER IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 176A3001 SHEET 22 REV D AND 176A3101 SHEET 4 REV -.;[02] CORRECTED STEP 1 REPLACED ANGLE LOCATED AT LEVEL BS1016 AND INTERNAL CAVITY ACCESS PANEL 323BL AT VERTICAL STABILIZER IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 176A3001 SHEET 22 REV D AND 176A3101 SHEET 4 REV -.SEE INDIDUAL SIGNOFF BELOW.;[03] REPLACED ANGLE LOCATED AT LEVEL BS1016 AND INTERNAL CAVITY ACCESS PANEL 323BL AT VERTICAL STABILIZER IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 176A3001 SHEET 22 REV D AND 176A3101 SHEET 4 REV -.SEE INDIDUAL SIGNOFF BELOW.<BR>TASK COMPLETED